Supashade, blackout blinds and awnings.

Motor Installation Notes

  1. This electrically operated blind should be connected to a 3 amp power supply by a qualified electrician and all earthing of the framework done to the regulations that are in place and that they correspond to the requirements of the building specification.
  2. Cable protection glands must be used when cable exits the blind box.
  3. Ensure that there is more than 300mm of space between each motor
  4. The power supply cable must not be cut back closer to the motor less than 1 metre.

Programming the motor

  1. Press the UP and DOWN buttons on the control switch simultaneously until the motor shunts up and down.
  2. Now check the direction configuration (down button to lower) is correct. If it's wrong, press stop button for 2 seconds until the motor shunts, this will change direction
  3. Press the UP button until the blind is fully up.
  4. Press the STOP and DOWN buttons together until the blind moves downwards.
  5. Stop the blind at he desired down position and make any adjustments using the UP and DOWN buttons to momentarily adjust the down position.
  6. Press the STOP and UP together to set the down limit. The blind will then move to the up position.
  7. When the blind has reached the up limit press the STOP button for 2 seconds until the motor shunts.
  8. Cut the main power and you have completed the factory mode and can begin the installer mode program.

Registering the handset

Press the UP and DOWN buttons on the control switch simultaneously until the motor shunts up and down. On the back of the transmitter is a small programming button. Press this button firmly until the blind shunts up and down. If this doesn't work first time, switch the power off and on and try again. Do not operate the handset closer that 500mm from the motor.

In the event of loosing a transmitter or no movement in the motor you can perform either of two resets.

Partial Reset (limited positions remain)

Using the motors main power supply : -

  1. Start with power on
  2. Power off for 4 secs
  3. Power on for 8 secs
  4. Power off for 4 secs
  5. Power on and wait as motor runs for 5 secs before stopping
  6. Press the program button on the rear of the transmitter for 2 seconds. A partial reset is confirmed by a single double shunt.

Total Memory Reset

Using the motors main power supply : -

  1. Start with power on
  2. Power off for 4 secs
  3. Power on for 8 secs
  4. Power off for 4 secs
  5. Power on and wait as motor runs for 5 secs before stopping
  6. Press the programme button for more than 8 seconds for a complete factory reset which will erase the motor's programming and all its settings and is confirmed by 2 sets of double shunts. You must now complete the factory mode for reprogramming the motor (see Programming the motor at the top of the page)
 

SUPA-SHADE Ltd, REGISTERED in ENGLAND No :-5578 569 COMPANY V.A.T. No :-867 1289 88